false
OasisLMS
Catalog
(FIT)-Module 5 Workshop 9: Arrhythmia Case Studies ...
Ellenbogen Case 7 Question
Ellenbogen Case 7 Question
Back to course
[Please upgrade your browser to play this video content]
Video Transcription
Video Summary
Case number 7, a 56-year-old female with recurrent syncopal spells times 10 years was found to have a normal cath, a normal echo, a normal stress test, and a normal EP study. The following was observed on a monitor the following day. The mechanism of the pause is most likely due to A, concealed conduction, B, high vagal tone, C, phase 4 block in the Hispokingy system, and D, phase 3 block in the AV node. I'm going to go on to the answer slide, so please work through this, pause your video now.
Keywords
syncopal spells
normal cath
normal echo
phase 4 block
AV node block
×
Please select your language
1